Binder Model CB 220 UL CO2 incubator with O2 control and hot air steri – Government Lab Enterprises

Binder

Binder Model CB 220 UL CO2 incubator with O2 control and hot air sterilization (7.4 cu. ft.)

  • Sale
  • Regular price $0.00

Shipping calculated at checkout.


Binder Model CB 220 CO2 incubator with O2 control and hot air sterilization (7.4 cu. ft.)

Manufacturer:  Binder

Model:  CB 220

Condition: New. Ships directly from the manufacturer

Warranty: 1 year manufacturer warranty plus additional year warranty after registration

Estimated lead time: If in stock, it will ship in 5 business days from acceptance of order. If out of stock, it will ship in 6-8 weeks after acceptance of order. Please contact us for availability. 

Important characteristics

  • Temperature range: room temperature plus 7 °C to 60 °C
  • Humidity range: up to 95% RH
  • O₂ control range: 0.2 to 20 vol% O₂ for versions with O₂ control
  • Alternative O₂ control range: 10 to 95 vol% O₂, option for versions with O₂ control
  • Auto-sterilization with hot air at 180 °C
  • Double-pan humidification system with condensation protection
  • CO₂ gas-mixing jet with Venturi effect
  • Hot-air sterilizable CO₂ sensor with infrared technology
  • Display via color LCD monitor
  • Lockable door handle
  • Tightly-sealed inner door made of tempered safety glass
  • Seamless, deep-drawn inner stainless steel chamber
  • 3 perforated stainless steel shelves
  • Units are stackable with stacking adapter
  • Troubleshooting system with visual and audible alarms
  • Computer interface: Ethernet
  • Internal data recording and USB interface
  • Zero-voltage alarm contact

Specifications

Designation CB220UL-120V-O
Option model with O2 control
Order number 9040-0099
Recovery time after 30 seconds door open at 37 °C [min] 5
Temperature fluctuation at 37 °C [± K] 0.1
Temperature range 7 °C above ambient temperature to [°C] 60
Temperature variation at 37 °C [± K] 0.4
Humidity range [% RH] 90 to 95
CO₂ measurement IR
CO₂ range [Vol.-% CO₂] 0 to 20
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] 5
O2 control ranges (vol% O2) 10 to 95
O2 recovery time after 30 sec door opening (min) 18
Standard O2 control range (vol% O2) 0.2 to 20
Nominal power [kW] 1.5
Phase (Nominal voltage) 1~
Power frequency [Hz] 50/60
Rated Voltage [V] 100 to 120
Unit fuse [A] 16
Inner doors 1
Unit doors 1
Interior dimensions (WxDxH) [in] 22.06 x 19.7 x 29.55
Interior volume [cu.ft.] 7.4
Load per rack [lbs] 22
Net weight of the unit (empty) [lbs] 267
permitted load [lbs] 66
Exterior dimensions (WxDxH) [in] 29.16 x 28.17 x 42.2
Wall clearance back [in] 3.94
Wall clearance sidewise [in] 1.97
Energy consumption at 37 °C [Wh/h] 120
Number of shelves (std./max.) 3/8